UltraDose Troubleshooting

Below are common conditions that are often addressed by our Technical Service department. Click on a condition below for product-specific troubleshooting. If you do not see your question listed, please feel free to contact Customer Service.

If you would like to troubleshoot a different product, click here.

Unit Is Not Pumping Fluid

If the motor is turning

  • check level of drain treatment supply
  • check for air leaks in the supply tubing connection to pump tube stems
  • check for clogs in inlet and outlet tubes
  • insure pump tube is not at all twisted
  • check pump tube. As it wears out, the amount of fluid pumped decreases. Change tube

If the motor is not turning

  • ensure programmer is functioning: Try to run pump manually (see page 3 of the instruction manual)
  • check program: Be sure both switches are in center position for programmed dispensing
  • check to insure wires from the electronic control to the motor are secure
  • ensure that wire from batteries to electronic control is secure
  • check battery condition. Try new batteries. BE SURE TIMER IS OFF before changing the batteries
  • remove the pump to see if pump is binding the motor (run motor manually -- see page 3 of the instruction manual)
Unit Is Pumping Too Much Fluid

The tubing is the proper ID for your application

  • check program to insure the required duration
  • ensure programmer is turning on and off at set times
  • remember that fresh batteries will result in a slightly higher than average dispense
The tubing is not the proper ID for your application

Solution: replace tubing with proper size.

Program time is locked up

Solution: Press reset. Reprogram timer.