UltraDose Troubleshooting
Below are common conditions that are often addressed by our Technical Service department. Click on a condition below for product-specific troubleshooting. If you do not see your question listed, please feel free to contact Customer Service.
If you would like to troubleshoot a different product, click here.
- Unit Is Not Pumping Fluid
-
If the motor is turning
- check level of drain treatment supply
- check for air leaks in the supply tubing connection to pump tube stems
- check for clogs in inlet and outlet tubes
- insure pump tube is not at all twisted
- check pump tube. As it wears out, the amount of fluid pumped decreases. Change tube
If the motor is not turning
- ensure programmer is functioning: Try to run pump manually (see page 3 of the instruction manual)
- check program: Be sure both switches are in center position for programmed dispensing
- check to insure wires from the electronic control to the motor are secure
- ensure that wire from batteries to electronic control is secure
- check battery condition. Try new batteries. BE SURE TIMER IS OFF before changing the batteries
- remove the pump to see if pump is binding the motor (run motor manually -- see page 3 of the instruction manual)
- Unit Is Pumping Too Much Fluid
-
The tubing is the proper ID for your application
- check program to insure the required duration
- ensure programmer is turning on and off at set times
- remember that fresh batteries will result in a slightly higher than average dispense
- The tubing is not the proper ID for your application
-
Solution: replace tubing with proper size.
- Program time is locked up
-
Solution: Press reset. Reprogram timer.